PrecisionBind Human Interleukin 15 (IL-15 / IL15) ELISA (NIBSC/WHO calibrated)

SKU: KBH0097

Rs 38,000.00

Enzyme Immunoassay for the estimation of Interleukin 15 (IL-15 / IL15) in human serum, plasma, cerebrospinal fluid and other biological samples.

PrecisionBind ELISA are matrix-evaluated cytokine immunoassays designed for immune monitoring and translational research, with reference-standard calibration (NIBSC/WHO where available) and performance documentation aligned to applied bioanalysis (ICH M12 for linearity, recovery, precision, and matrix effects). RUO only.

Sample matrices Validated: Serum, Plasma, Cerebrospinal Fluid, Cell Culture Supernatant and Cell / Tissue Lysates

Assay Range: 15.6 – 1000 pg/ml | Sensitivity: 3.62 pg/ml

Availability: 3 – 4 Weeks | Pack Size: 1 x 96 wells, break-apart

9 in stock

Free worldwide shipping on all orders over $3000

 

 

Guaranteed Safe Checkout

All our kits are manufactured under ISO 13485.

The precisionbind Human Interleukin 15 (IL-15 / IL15) ELISA includes features like:
Ready to use protocol with break-apart wells for ease of use
Standardisation and High Reproducibility
Lot to Lot Consistency
Accuracy and Precision

Principle Of Assay: This ELISA is a sandwich immunoassay. Antibodies are coated on 96 well plates. The antigen protein present in sample and standard respectively bind to the coated wells. The wells are washed and an antibody:HRP Conjugate is added which binds to the bound complex in the well. Washing is performed to remove any unbound material. TMB substrate is added and the enzyme reaction is stopped by dispensing of stop solution into the wells. The optical density (OD) of the solution at 450 nm is directly proportional to the amount of antigen protein present in the standard or samples.

Disclaimer: The data indicated herein with specifications are changed from time to time at time of production of the assay. We request you to confirm the specifications including the assay range and procedure as per the most current IFU (instructions for use) accompanying the assay kit.

Validated against seven points for a GOLD RING Standard Quality ELISA the benchmark sign for Krishgen Quality. The precisionbind ELISAs are used for assessing the specific biomarker in samples analytes which may be human serum, plasma, biological fluids and cell culture supernatant and uses monoclonal antibodies to ensure a high degree of specificity and reagents of superior quality to offer a sensitive assay. For project based larger number ofs, talk to us to offer you our validation guide for the same.

About PrecisionBind:
PrecisionBind is Krishgen`s cytokine ELISA platform developed for bioanalytical robustness in translational research, including immuno-oncology and cell & gene therapy programs. Where applicable, kit standards are calibrated against NIBSC/WHO international standards to support unit traceability and inter-study comparability.

Assays are characterized following ligand-binding assay performance expectations, including:

  • Defined assay range and sensitivity (LOD/LOQ where reported)
  • Intra- and inter-assay precision
  • Cross-matrix performance characterization (serum, plasma, CSF where applicable), including parallelism and recovery assessment, to support quantitative comparability across biological matrices.

    All kits are Research Use Only (RUO) and not intended for diagnostic use.

  • Additional information

    Pack Type

    1 x 96 wells, break-apart

    Species Reactivity

    Homo Sapiens (Human)

    Sample Type

    cell lysates, cerebrospional cell culture supernates and other biological fluids. K2EDTA serum and plasma validated only. For tear samples, plasma, please connect with us to discuss further., Serum, tissue homogenates

    Short Name

    Interleukin 15 (IL-15 / IL15) ELISA

    Assay Range

    15.6 – 1000 pg/ml

    Standards Available

    0; 15.6 ; 31.25; 62.5; 125; 250; 500; 1000 pg/ml

    Analytical Sensitivity: LOD

    3.62 pg/ml

    Functional Sensitivity: LOQ

    10.97 pg/ml

    IC50%

    ~921 pg/ml

    Calibration Curve

    8 point; standards available

    Interference

    Preparations of the known factors were assayed for interference. No significant interference was observed.

    Specificity

    The assay uses monoclonal antibody against the analyte and is highly specific as a capture protein.

    Principle Of Assay

    Double Antibody, Sandwich ELISA

    Detection Method

    Absorbance measured at 450nm, Colorimetric

    Conjugate-Enzyme Reaction

    Uses stable HRP Enzyme Conjugate with (single component) TMB Chromogenic Substrate for color development.

    Regulatory Status

    Research Use Only.

    Shipping Temperature

    Shipped at Room Temperature or in gel pack to maintain temperature at 2-8 degrees Celsius

    Storage Temperature

    if all the wells in the kit are not being used, store the unused wells in the foil pouch containing the desiccant pack, The kit (2-8 Degree Celsius) and its components are to be stored as indicated in the IFU (instructions for use). To ensure quality of your results

    ELISA Interpretation

    4PL (2nd order) or Cubic Spline Graph. Software (MS Excel) available, on request, Quantitative Results Intepretation, to support interpretation of results.

    Shelf Life Available

    8 -10 months at time of shipping

    Alternate Names / Synonyms

    Interleukin 15; IL-15; IL15; MGC9721 Protein

    Research Area

    Cell Therapy, Immune molecule; Cell Biology; Immunology; Gene Therapy

    Disclaimer

    The data indicated herein with specifications are changed from time to time at time of production. Please refer the most current IFU (instructions for use) accompanying the kit.

    Documents

    PrecisionBind Human IL-15-ELISA-Validation_Guide_2025_ver 1.0