PrecisionBind Human Interleukin 8 / IL-8 / Interleukin-8 ELISA

SKU: KB1070

Rs 30,000.00

Enzyme Immunoassay for the estimation of Human Interleukin 8 / IL 8 / IL-8 / Interleukin-8 ELISA in serum, plasma, cell culture supernatant and other biological samples.

Assay Range: 0 – 1000 ng/ml* (May vary. Please confirm) | Sensitivity: 30 ng/ml* (May vary. Please confirm)

Availability: 3 – 4 weeks | Pack Size: 1 x 96 wells

Free worldwide shipping on all orders over $3000

 

 

Guaranteed Safe Checkout

All our kits are manufactured under ISO 13485.

The GENLISA Human Interleukin 8 (IL8) ELISA includes features like:
– Ready to use protocol with break-apart wells for ease of use
– Standardisation and High Reproducibility
– Lot to Lot Consistency
– Accuracy and Precision

Principle Of Assay: This ELISA is a sandwich immunoassay. Antibodies are coated on 96 well plates. The antigen protein present in sample and standard respectively bind to the coated wells. The wells are washed and an antibody:HRP Conjugate is added which binds to the bound complex in the well. Washing is performed to remove any unbound material. TMB substrate is added and the enzyme reaction is stopped by dispensing of stop solution into the wells. The optical density (OD) of the solution at 450 nm is directly proportional to the amount of antigen protein present in the standard or samples.

Disclaimer: The data indicated herein with specifications are changed from time to time at time of production of the assay. We request you to confirm the specifications including the assay range and procedure as per the most current IFU (instructions for use) accompanying the assay kit.

Validated against seven points for a GOLD RING Standard Quality ELISA – the benchmark sign for Krishgen Quality. The The GENLISA ELISA kits are used for assessing the specific biomarker in samples analytes which may be human serum, plasma, biological fluids and cell culture supernatant. The kit uses indirect sandwich assay with double antibodies – capture and detection to ensure a high degree of sensitivity and specificity in the estimation of Interleukin 8 (IL8);

Validation Parameters and Acceptance Criteria

1. IL-8 Cmax Values and Recommended ELISA Range
Note: Assay sensitivity <5 pg/mL recommended for baseline detection; upper limit ≥5,000 pg/mL advised for CRS monitoring

The PrecisionBind Human IL-8 ELISA kit is developed using an assay range of 7.8 – 500 pg/ml with the dilutional linearity accuracy to measure responses as per the application table above on patient Cmax values. The kit has also been validated upto 1600 fold dilution
and the values are within the acceptable range.

2. Specificity and Selectivity
2.1 Specificity
The capture antibody and detection antibody are both specific to IL-8 and are monoclonal antibodies. They show a high affinity to bind to native as well as recombinant IL-8.

2.2 Selectivity
The ELISA has no or low cross reactivity to IL‑1β (IL-1beta), IL‑6, or TNF‑β (TNFbeta).

2.3 NIBSC validation
The standard used in the kit is calibrated against an international standard from the National Institute of Biological Standards and Control (NIBSC), Potters Bar, Hertfordshire EN6 3QG, UK. 1 ng of supplied standard equals 580 U of 93/730 NIBSC-standard.
Therefore 1000 pg/ml is equivalent to 580 U of IL-8 as per NIBSC.

2.4 LOD, LOQ and IC50
LOD (Limit of Detection)
The lowest analyte concentration that can be reliably distinguished from blank/background noise but not necessarily quantified precisely.

Statistically:
LOD = Mean of Blank + 3X SD of Blank
(3σ criterion is most common).
LOD for PrecisionBind Human IL-8 ELISA = 0.2 pg/ml

LOQ (Limit of Quantitation)
The lowest analyte concentration that can be quantified with acceptable accuracy and precision.

Statistically:
LOQ = Mean of Blank + 10X SD of Blank
(10σ criterion is most common).
LOQ for PrecisionBind Human IL-8 ELISA – 0.6 pg/ml

IC50 in ELISA (Half Maximal Inhibitory Concentration)
IC50 = The concentration of an inhibitor (drug, antibody, compound) required to reduce the signal (e.g., binding, enzymatic activity) by 50% compared to the maximum signal in the assay.

In ELISA, this is commonly used for:
Neutralization ELISA: Quantifies potency of antibodies inhibiting target–ligand interaction.
Drug Potency Testing: Measures concentration at which drug inhibits 50% of target activity.

IC50 for PrecisionBind Human IL-8 ELISA = ~224 pg/ml

Regulatory Note:
LOD S/N ≥ 3:1, LOQ ≥ 10:1, %CV ≤ 20% *S/N = Signal / Noise Ratio

3. Linearity and Range

4. Accuracy and Precision (Intra/Inter-Assay)

A.) Intra-assay:

B.) Inter assay:

5. Parallelism and Matrix Effect
Sample Dilution factor – Human Serum, Human Plasma and Human CSF samples have been tested. Sample dilution Factor for all three matrices is 1:50 dilution.
Neat Human Serum, Human Plasma and Human CSF were spiked with 250 pg/ml Human IL-8 and ELISA assay was run.

A) Serum:

B) Plasma:

C) Cerebrospinal Fluid (CSF):

Results:
i) Parallelism is maintained across the 1:100 to 1:1600 dilutions.
ii) % Recovery for most dilutions falls within the acceptable range of 80%–120%.
iii) No significant matrix effect observed at higher dilutions.
iv) The PrecisionBind Human IL-8 ELISA kit was tested for matrix effect on human serum, plasma, CSF and physiological buffer 7.4 to mimic tear fluid samples.

6. Sample Handling and Storage Conditions

A) Sample collection and handling:
Specimens should be clear and non-hemolyzed. Samples should be run at a number of dilutions to ensure accurate quantitation.

Cell Culture Supernatant: If necessary, centrifuge to remove debris prior to analysis. Samples can be stored at temperature <-20°C. Avoid repeated freeze/thaw cycles.

Serum: Use a serum separator tube and allow clotting for 30 minutes, then centrifuge for 10 minutes at 1000 x g. Remove serum layer and assay immediately or store serum samples at temperature <-20°C. Avoid repeated freeze/thaw cycles.

Plasma: Collect blood sample in a citrate, heparin or EDTA containing tube. Centrifuge for 10 minutes at 1000 x g within 30 minutes of collection. Assay immediately or store plasma samples at temperature <-20°C. Avoid repeated freeze/thaw cycles.

B) Storage conditions:
Store main kit components at 2-8°C.
Store recombinant lyophilized standard at 2-8°C. Upon reconstitution aliquot standards into polypropylene vials and store at -20°C as per assay requirements. Do not freeze thaw for more than two times.
Before using, bring all components to room temperature (18-25°C). Upon assay
completion return all components to appropriate storage conditions.

Graphs, Maps and Appendices:

Calibration of Standard Used in the KIT

Determined Limits for Acceptance according to EMA/FDA and CLSI regulations

References
Meier, C., & Brieger, A. (2025). The role of IL-8 in cancer development and its impact on immunotherapy resistance. European Journal of Cancer, 218, 115267.
https://doi.org/10.1016/j.ejca.2025.115267

Benakanakere, M. R., Finoti, L. S., Tanaka, U., Grant, G. R., Scarel-Caminaga, R. M., & Kinane, D. F. (2016). Investigation of the functional role of human Interleukin-8 gene haplotypes by CRISPR/Cas9 mediated genome editing. Scientific Reports, 6(1).
https://doi.org/10.1038/srep31180

FDA Guidance for Industry: Immunogenicity Assessment for Therapeutic Protein Products (2014).

EMA Guideline on Biosimilar Monoclonal Antibodies (2012).

Additional information

Species Reactivity

Human

Sample Type

Cell Culture Supernatant and other biological samples. Validated for citrated/EDTA Plasma only., plasma, Serum

Assay Range

0 – 1000 ng/ml* (May vary. Please confirm)

Standards Available

* request IFU

Sensitivity

30 ng/ml* (May vary. Please confirm)

Interference

Preparations of the known factors were assayed for interference. No significant interference was observed.

Principle Of Assay

Double Antibody, Sandwich ELISA

Detection Method

Absorbance measured at 450nm, Colorimetric

Conjugate-Enzyme Reaction

Uses stable HRP Enzyme Conjugate with (single component) TMB Chromogenic Substrate for color development.

Quality Certification

Validated as per KRISHGEN's Quality Program. GOLD PLUS (GOLD+) validation done. The kit is calibrated against NIBSC calibrator.

Regulatory Status

Research Use Only.

Shipping Temperature

Shipped at Room Temperature or in gel pack to maintain temperature at 2-8 degrees Celsius

ELISA Interpretation

4PL (2nd order) or Cubic Spline Graph. Software (MS Excel) available, on request, Quantitative Results Intepretation, to support interpretation of results.

Shelf Life Available

8 -10 months at time of shipping

Alternate Names / Synonyms

Interleukin 8 (IL8);

Research Area

Immune molecule

Disclaimer

The data indicated herein with specifications are changed from time to time at time of production. Please refer the most current IFU (instructions for use) accompanying the kit.

Documents

PrecisionBind Human IL-8-ELISA-Validation_Guide_2025_ver 1.0